FCL High Viscosity Filter Cart
Order and customize your order quickly and easily.
FCL Specifications
Dimensions1 |
Height
57” (144 cm) |
Width
30” (77 cm) |
Depth
30” (77 cm) |
Weight
351 lbs (159 kg) |
||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Connections |
Inlet
FCL05-FCL5: 1” male JIC (37° flare) FCL10: 1.25” male JIC (37° flare) |
Outlet
FCL05-FCL10: 1” male JIC (37° flare) FCL20-FCL30: 1.25” male JIC (37° flare) |
Hoses
FCL05-FCL5: 1” x 10 ft (2.4 m) FCL10: 1.25” x 10 ft (2.4 m) suction |
|||||||||
Operating Temperature |
Fluid Temperature
30°F to 225°F (0°C to 105°C) |
Ambient Temperature
-4°F to 104°F (-20C to 40C) |
||||||||||
Materials of Construction |
Housing
Carbon steel with industrial coating |
Hoses
Reinforced synthetic |
Wands
Stainless steel |
|||||||||
Electric Motor | TEFC, 56-215 frame 0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings. |
|||||||||||
Electric Connection | Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) loose cord included. | |||||||||||
Motor Starter | MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection. | |||||||||||
Pump | Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. | |||||||||||
Pump Bypass | Full bypass at 150 psi (10 bar)2 | |||||||||||
Pneumatic Option Air Consumption | ~40 cfm @ 80 psi3 35’ (11 m) retractable air hose included when pneumatic option selected. Replaces 35’ (11m) electric cord reel. | |||||||||||
Media Description |
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] = 1000 (βx = 200) |
A
Microglass high performance media combined with water removal scrim. βx[C] = 1000 (βx = 200) |
W
Stainless steel wire mesh media βx[C] = 2 (βx = 2) |
VTM
β0.9[C] = 1000 particulate, insoluble oxidation by-product and water removal media |
||||||||
Viscosity | 2-5000 cSt4 | |||||||||||
Fluid Compatibility | Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options. | |||||||||||
Hazardous Environment Options | Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included. |