FCL Specifications

Get detailed information about the FCL

Dimensions1 Height

57” (144 cm)

Width

30” (77 cm)

Depth

30” (77 cm)

Weight

351 lbs (159 kg)

Connections Inlet

FCL05-FCL5: 1” male JIC (37° flare)

FCL10: 1.25” male JIC (37° flare)

Outlet

FCL05-FCL10: 1” male JIC (37° flare)

FCL20-FCL30: 1.25” male JIC (37° flare)

Hoses

FCL05-FCL5: 1” x 10 ft (2.4 m)

FCL10: 1.25” x 10 ft (2.4 m) suction
1” x 10 ft (2.4 m) discharge

Operating Temperature Fluid Temperature

30°F to 225°F

(0°C to 105°C)

Ambient Temperature

-4°F to 104°F

(-20C to 40C)

Materials of Construction Housing

Carbon steel with industrial coating

Hoses

Reinforced synthetic

Wands

Stainless steel

Electric Motor TEFC, 56-215 frame
0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings.
Electric Connection Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) loose cord included.
Motor Starter MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption ~40 cfm @ 80 psi3 35’ (11 m) retractable air hose included when pneumatic option selected. Replaces 35’ (11m) electric cord reel.
Media Description M

Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] = 1000 (βx = 200)

A

Microglass high performance media combined with water removal scrim. βx[C] = 1000 (βx = 200)

W

Stainless steel wire mesh media βx[C] = 2 (βx = 2)

VTM

β0.9[C] = 1000 particulate, insoluble oxidation by-product and water removal media

Viscosity 2-5000 cSt4
Fluid Compatibility Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included.
  • Dimensions are approximations taken from base model and will vary according to options chosen.
  • 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
  • Air consumption values are estimated maximums and will vary with regulator setting
  • When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.